采光井脚手架
![8号楼采光井架底未封闭.](https://i.ecywang.com/upload/1/img2.baidu.com/it/u=1689154224,3723257686&fm=253&fmt=auto&app=138&f=JPEG?w=375&h=500)
8号楼采光井架底未封闭.
图片尺寸2000x2667![(5)综合楼三层屋面南段采光井脚手架搭设完毕](https://i.ecywang.com/upload/1/img1.baidu.com/it/u=2372844133,3524830606&fm=253&fmt=auto&app=138&f=JPEG?w=500&h=375)
(5)综合楼三层屋面南段采光井脚手架搭设完毕
图片尺寸1200x900![一号区顶楼采光井施工中](https://i.ecywang.com/upload/1/img1.baidu.com/it/u=1859559039,2436451900&fm=253&fmt=auto&app=138&f=JPEG?w=667&h=500)
一号区顶楼采光井施工中
图片尺寸2667x2000![7号楼采光井架无连墙件.](https://i.ecywang.com/upload/1/img0.baidu.com/it/u=3722460183,3116202417&fm=253&fmt=auto&app=138&f=JPEG?w=500&h=667)
7号楼采光井架无连墙件.
图片尺寸2000x2667![2#8#采光井脚手架防护未跟上.](https://i.ecywang.com/upload/1/img2.baidu.com/it/u=1603081856,1388553357&fm=253&fmt=auto&app=138&f=JPEG?w=667&h=500)
2#8#采光井脚手架防护未跟上.
图片尺寸800x600![改建区域1#采光井脚手架连墙连缺失,架体损坏变形未修复,立面剪刀撑](https://i.ecywang.com/upload/1/img2.baidu.com/it/u=1727173143,2764507273&fm=253&fmt=auto&app=138&f=JPEG?w=667&h=500)
改建区域1#采光井脚手架连墙连缺失,架体损坏变形未修复,立面剪刀撑
图片尺寸1440x1080![采光井架体脚手板未绑扎牢固](https://i.ecywang.com/upload/1/img1.baidu.com/it/u=2755093115,1438265335&fm=253&fmt=auto&app=138&f=JPEG?w=667&h=500)
采光井架体脚手板未绑扎牢固
图片尺寸4032x3024![3号楼采光井架体连墙件不足!](https://i.ecywang.com/upload/1/img2.baidu.com/it/u=4020108387,914532834&fm=253&fmt=auto&app=138&f=JPEG?w=500&h=667)
3号楼采光井架体连墙件不足!
图片尺寸1080x1440![各楼层内采光井位置的外架立杆离墙距过大,未加设防护](https://i.ecywang.com/upload/1/img0.baidu.com/it/u=2647203968,2745665087&fm=253&fmt=auto&app=138&f=JPEG?w=375&h=500)
各楼层内采光井位置的外架立杆离墙距过大,未加设防护
图片尺寸2000x2667![采光井内架未跟上,未铺一张脚手片](https://i.ecywang.com/upload/1/img2.baidu.com/it/u=2908140777,916220302&fm=253&fmt=auto&app=138&f=JPEG?w=500&h=375)
采光井内架未跟上,未铺一张脚手片
图片尺寸4032x3024![各楼层内采光井位置的外架离墙距过大,未设防护](https://i.ecywang.com/upload/1/img1.baidu.com/it/u=325605004,150272471&fm=253&fmt=auto&app=138&f=JPEG?w=500&h=667)
各楼层内采光井位置的外架离墙距过大,未设防护
图片尺寸2000x2667![脚手架卸荷钢丝绳油浸污染,端部散股未绑扎,绳卡间距过大,采光井部位](https://i.ecywang.com/upload/1/img2.baidu.com/it/u=474420817,3201352155&fm=253&fmt=auto&app=138&f=JPEG?w=500&h=667)
脚手架卸荷钢丝绳油浸污染,端部散股未绑扎,绳卡间距过大,采光井部位
图片尺寸2000x2666![4号楼南侧采光井16层无连墙件!](https://i.ecywang.com/upload/1/img1.baidu.com/it/u=4244152277,1492116571&fm=253&fmt=auto&app=138&f=JPEG?w=375&h=500)
4号楼南侧采光井16层无连墙件!
图片尺寸1080x1440![叶县昆北城雕公园建设项目日报(10.23)](https://i.ecywang.com/upload/1/img1.baidu.com/it/u=2708503042,937480857&fm=253&fmt=auto&app=138&f=JPEG?w=667&h=500)
叶县昆北城雕公园建设项目日报(10.23)
图片尺寸2667x2000![采光井处脚手架立杆悬空](https://i.ecywang.com/upload/1/img0.baidu.com/it/u=341359092,1988408084&fm=253&fmt=auto&app=138&f=JPEG?w=499&h=310)
采光井处脚手架立杆悬空
图片尺寸554x344![居民说是采光井 物业说是消防救援](https://i.ecywang.com/upload/1/img1.baidu.com/it/u=2608662997,4133083573&fm=253&fmt=auto&app=138&f=JPEG?w=640&h=480)
居民说是采光井 物业说是消防救援
图片尺寸640x480![30_玉龙河综合整治二期工程施工日报 写美篇4,y7调蓄池管道检查井施工](https://i.ecywang.com/upload/1/img1.baidu.com/it/u=3543806116,1693794152&fm=253&fmt=auto&app=138&f=JPEG?w=667&h=500)
30_玉龙河综合整治二期工程施工日报 写美篇4,y7调蓄池管道检查井施工
图片尺寸4032x3024![采光井洞内脚手架防护材料堆放整齐电缆线定型化钢盖板防护定型化钢板](https://i.ecywang.com/upload/1/img1.baidu.com/it/u=3569850140,2406234253&fm=253&fmt=auto&app=138&f=JPEG?w=408&h=614)
采光井洞内脚手架防护材料堆放整齐电缆线定型化钢盖板防护定型化钢板
图片尺寸408x614![与采光井架距离太远存在空洞](https://i.ecywang.com/upload/1/img0.baidu.com/it/u=3751538319,4128409818&fm=253&fmt=auto&app=138&f=JPEG?w=500&h=375)
与采光井架距离太远存在空洞
图片尺寸1125x844![各楼层内采光井位置的外架立杆离墙距过大,未设防护](https://i.ecywang.com/upload/1/img1.baidu.com/it/u=1444666184,983443703&fm=253&fmt=auto&app=138&f=JPEG?w=500&h=667)
各楼层内采光井位置的外架立杆离墙距过大,未设防护
图片尺寸2000x2667